Linton Falls Accessible Toilet Extension
Site Location Plan
Scale: 1:1250
IMAGE: Site location plan showing the proposed area of works outlined in red and the site ownership boundary outlined in blue. The plan covers Church Road, the car park, Great Bank, PCs, Holme House, Sheepfold and Track, with the site located near the car park. A north arrow and a scale bar from 0 to 150 metres are shown.
Notes
This Drawing is an instrument of service and shall remain the property of Align Property Partners Ltd copyright ©. It may not be reproduced or copied in any form. It shall not be used for the construction, enlargement or alteration of a building or area other than the said project without the authorisation of the issuing office.
Contractors shall verify and be responsible for all dimensions and conditions and shall report any discrepancies to the issuing office before proceeding with any work. Drawings shall not be scaled.
This map is reproduced from Ordnance Survey material with the permission of Ordnance Survey on behalf of the Controller of Her Majesty’s Stationery Office © Crown copyright. Unauthorised reproduction infringes Crown copyright and may lead to prosecution or civil proceedings.
North Yorkshire County Council 100017946 2023
Key
- Proposed Area of Works
- Site Ownership Boundary
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Falls Accessible Toilet Extension |
| Drawing Title | Site Location Plan |
| Purpose | BR |
| Scale | 1:1250 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A3 |
| Date | 14/10/26 |
| Checked Date | 30/10/26 |
| Approved Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-100 |
| Version | P1 |
| File | YD2603-APP-XX-XX-DR-B-100 Site Location Plan.dwg |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Align Property Partners Ltd©copyright © 2026 Align
Existing Site Plan
Scale: 1:100
IMAGE: Existing site plan showing Church Road, the car park and Great Bank. Existing manholes are marked MH, including an MH marked redundant. The site ownership boundary is outlined in blue. The plan identifies existing drainage.
Notes
This Drawing is an instrument of service and shall remain the property of Align Property Partners Ltd copyright ©. It may not be reproduced or copied in any form. It shall not be used for the construction, enlargement or alteration of a building or area other than the said project without the authorisation of the issuing office.
Contractors shall verify and be responsible for all dimensions and conditions and shall report any discrepancies to the issuing office before proceeding with any work. Drawings shall not be scaled.
This map is reproduced from Ordnance Survey material with the permission of Ordnance Survey on behalf of the Controller of Her Majesty’s Stationery Office © Crown copyright. Unauthorised reproduction infringes Crown copyright and may lead to prosecution or civil proceedings.
North Yorkshire County Council 100017946 2023
Key
- Proposed Area of Works
- Site Ownership Boundary
- Existing Drainage
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | Existing Site Plan |
| Purpose | BR |
| Scale | 1:100 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A1 |
| Date | 14/10/26 |
| Checked Date | 30/10/26 |
| Approved | P1 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-01 |
| Version | P1 |
| File | YD2603-APP-XX-XX-DR-B-101 Existing Site Plan.dwg |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Align Property Partners Ltd©copyright © 2025 Align
Proposed Site Plan, Roof Plan & Indicative Drainage Layout
Scale: 1:50
IMAGE: Proposed site and roof plan showing the proposed accessible toilet extension within the site ownership boundary. The plan identifies the existing assumed combined drainage system, existing and redundant manholes, new inspection chamber, new 100 mm diameter underground drain, new soil vent pipe, rainwater pipes and the proposed accessible toilet extension. Typical drainage details are shown separately.
Note
The proposed layouts shown are indicative only. The final design for the proposed drainage and connections into existing rests with the principal contractor.
Notes
This Drawing is an instrument of service and shall remain the property of Align Property Partners Ltd copyright ©. It may not be reproduced or copied in any form. It shall not be used for the construction, enlargement or alteration of a building or area other than the said project without the authorisation of the issuing office.
Contractors shall verify and be responsible for all dimensions and conditions and shall report any discrepancies to the issuing office before proceeding with any work. Drawings shall not be scaled.
This map is reproduced from Ordnance Survey material with the permission of Ordnance Survey on behalf of the Controller of Her Majesty’s Stationery Office © Crown copyright. Unauthorised reproduction infringes Crown copyright and may lead to prosecution or civil proceedings.
North Yorkshire County Council 100017946 2023
Key
- Proposed Area of Works
- Site Ownership Boundary
Drainage Annotations
- Existing (assumed) combined drainage system
- New 100mmØ underground drain with new inspection chamber connected into existing combined system; maximum fall 1:50
- New svp
- rwp
- MH
- MH (redundant)
- IC
- Proposed accessible toilet extension
Typical Polypropylene Inspection Chamber Installation Plan Detail
- Main Flow
- Where chambers are positioned on 90° corners always use the main channel by fitting a 45° bend code SB1/2 on inlet and outlet
- PPIC - 150 mm inlet code
- SPIC1/1 940 mm deep code
- SPIC2/1 595 mm deep
- Bends of up to max 45° angle can be used on any inlet and the outlet
- Heaviest flow should always be directed through main channel
- Short steep branch connections should preferably be connected via a 45° inlet using a bend where necessary
Surface Water Access Gully Connection
- Waste or rainwater pipe up to maximum 68 mm diameter
- Hinged metal Grid - code IH1 (Alloy)
- Access Gully code SG3/1
- Concrete bed
- Bend to suit
- G.L.
- F.F.L.
- Concrete Bed
Roads and Footpaths with Standard Round Cover
- Round Ductile Iron cover & frame Type as specified
- 225 mm deep concrete plinth to support finish
- Polypropylene Inspection Chamber code SPIC1/1 - 940 mm deep code SPIC1/2 - 595 mm deep max 1.0 Metre deep
- Well compacted bedding matrial used as backfill
- NB - Universal Product - Adaptor to pvc-u pipe included
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | Proposed Site Plan & Roof Plan; Indicative Drainage Layout & Typical Details |
| Purpose | BR |
| Scale | 1:50 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A1 |
| Date | 14/10/26 |
| Checked Date | 30/10/26 |
| Approved Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-102 |
| Version | P1 |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Existing Floor Plan
Scale: 1:50
IMAGE: Existing floor plan showing the existing toilets, including Female Toilets, Male Toilets and Store, together with the surrounding bitmac hardstanding and the site ownership boundary.
Notes
This Drawing is an instrument of service and shall remain the property of Align Property Partners Ltd copyright ©. It may not be reproduced or copied in any form. It shall not be used for the construction, enlargement or alteration of a building or area other than the said project without the authorisation of the issuing office.
Contractors shall verify and be responsible for all dimensions and conditions and shall report any discrepancies to the issuing office before proceeding with any work. Drawings shall not be scaled.
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | Existing Floor Plan |
| Purpose | BR |
| Scale | 1:50 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A2 |
| Date | 14/10/26 |
| Checked Date | 30/10/26 |
| Approved Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-103 |
| Version | P1 |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Align Property Partners Ltd©copyright © 2026 Align
General Arrangement Floor Plan
Scale: 1:50
IMAGE: General arrangement floor plan showing the proposed accessible toilet extension beside the existing Female Toilets, Store and Male Toilets. The plan includes the Paying Station, dimensions, door reference ED01 and window reference EW01.
Door & Window Schedule
Scale: NTS
Glazing Types
| Reference | Description |
|---|---|
| FL | Fixed light |
| OL | Opening light |
| TV | Trickle ventilation |
| OP | Opaque glass panel |
External Door Schedule
| External Door | Location | Structural Opening Height (mm) | Structural Opening Width (mm) | Frame | RAL | Ironmongery | Glazing | Glazing Security | Type | Manifestations | Fire Rating | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ED01 | Acc WC | 2125 | 1224 | Softwood | Stained to match existing | 1 ½ pairs ss butt hinges; Push/pill plates; Radar keyset lock | N/a | N/a | 1 | N/a | N/a | To match existing doors. Check dimensions on site |
Window Schedule
| Window Ref | Location | Structural Opening Height (mm) | Structural Opening Width (mm) | Frame | Ironmongery | Glazing | Glazing Security | Type | Manifestations | Fire Rating | Comments |
|---|---|---|---|---|---|---|---|---|---|---|---|
| EW01 | Acc WC | 1240 | 460 | Softwood | 1 pair casement hinges; Lockable casement stay | D. glazed | N/a | 1 | N/a | N/a | To match existing windows. Check dimensions on site |
General Notes
Full details to be provided to Yorkshire Dales National Park Authority for comment prior to fabrication. Contractor to ensure robust weather seals are installed with 15mm maximum threshold difference for DDA.
U-value of glazing to achieve 1.3Wm2K or better. Trickle vents to be included to comply with Building Regulations to all opening lights.
NOTE:
All dimensions are to be measured on site by the contractor prior to fabrication.
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | General Arrangement Floor Plan; Door & Window Schedule |
| Purpose | BR |
| Scale | 1:50 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A2 |
| Date | 14/10/26 |
| Checked Date | 30/10/26 |
| Approved Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-104 |
| Version | P1 |
| File | YD2603-APP-XX-XX-DR-B-104 GA Floor Plan.dwg |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Proposed Floor Plan
Scale: 1:20
IMAGE: Proposed floor plan showing the accessible toilet extension, its dimensions, door threshold drainage channel, new SVP, new floor penetrations, proposed finishes and the relationship to the existing toilet building. Notes identify vinyl safety flooring, hygienic wall cladding, plasterboard ceilings, a hinged support rail, low-level drainage and the treatment of an existing window opening.
Proposed Floor Plan Notes
- Vinyl safety flooring to be Polysafe Quattro PUR Safety Floor; or equal and approved; allow CF38 cove formers and CS capping strip to wall perimeters; colour tbc
- Walls to be clad with Altro Whiterock Satins hygienic wall cladding, or equal and approved; thickness 2.5mm; colour tbc
- Ceilings to be 12.5mm plasterboard fixed to u/s of ceiling joists; skim coat and emulsion paint finish
- Hinged support rail; 800mm x 35mm diameter; colour tbc
- 110mm Ø above ground drainage at low level and boxed in with exterior grade plywood, decorated
- Existing window removed and opening blocked up in 100mm lightweight blockwork; plasterboard and skim both sides; cavity full filled with two layers 90mm Rockwool insulation
- Existing hand wash/dryer unit to be carefully taken out and set aside to facilitate the removal of the existing window; reinstated and recommissioned upon completion
- 100mm ACO MultiDrain PPD drainage channel to door threshold, or equal and approved; connected into new SVP
- Norseal NOR630 aluminium threshold plate to door threshold; or equal and approved
Indicative M&E Layout
Scale: 1:20
IMAGE: Indicative mechanical and electrical layout showing the accessible toilet fittings and electrical services, including lighting, extract fan, sound beacon, assistance alarm, emergency lighting key switch, reset button, alarm button and electric panel heater.
M&E Key
- Fused spur
- Bathroom extract fan
- Sound beacon
- Downlight LED luminaire
- Assistance alarm pull cord
- Emergency lighting key switch
- Push reset button
- Alarm button
- Dimplex 750W tamper proof electric panel heater, ref; PXL075ENC; or equal and approved; final position tbc
Room Elevations
Scale: 1:20
IMAGE: Four room elevations, labelled Elevation A, Elevation B, Elevation C and Elevation D, showing the accessible toilet fittings, grab rails, mirror, dispensers, hand dryer, splashback, WC pan, pull rail and door hardware.
Room Elevation Annotations
- Alarm pull cord with 2no. red bangles (100mm and 900mm AFFL)
- 600 x 35mm dia. grab rails fixed at heights in accordance with Building Regulations Part M; colour tbc
- 300x700mm mirror fixed 600mm above FFL
- Toilet paper dispenser
- Soap dispenser
- Automatic hand dryer
- 150mm high uPVC splashback
- Raised height Doc M WC pan
- 1026 door leaf; door to match doors to existing toilet building
- 450 x 35mm dia. pull rail fixed at 900mm off FFL; colour tbc
- Accessible Radar NKS lockset for public toilet door
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | Proposed Floor Plan & Room Elevations; Indicative M&E Layout |
| Purpose | BR |
| Scale | 1:20 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A1 |
| Date | 20/10/26 |
| Checked Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-105 |
| Version | P1 |
| File | YD2603-APP-XX-XX-DR-B-105-Proposed Floor Plan & Indicative M&E Layout.dwg |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Proposed Elevations
Scale: 1:50
IMAGE: Proposed north, south, east and west elevations of the accessible toilet extension, with a floor plan key showing the orientation of the elevations. The elevations identify existing and proposed stone, slate roof tiles, windows, doors, rainwater goods, lintels, sills and the proposed soil vent pipe. A defibrillator is marked on the north and south elevations.
Materials Key
| No. | Material |
|---|---|
| 1 | Existing stone - limestone |
| 2 | Existing roof tiles - natural slate, colour grey |
| 3 | Existing windows - frame colour white, clear glazing |
| 4 | Existing door - frame and leaf colour brown |
| 5 | Existing rainwater goods - metal painted colour white |
| 6 | Existing lintels & sills - natural stone |
| 7 | Proposed stone to match existing - limestone |
| 8 | Proposed roof tiles to match existing - natural slate, colour grey |
| 9 | Proposed PVC window - frame colour white, obscure glazing |
| 10 | Proposed hardwood timber door and frame frame and leaf colour blue |
| 11 | Proposed rainwater goods to match existing - ppc aluminium colour white |
| 12 | Proposed lintels & sills - natural stone |
| 13 | Proposed SVP - ppc aluminium colour white |
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | Proposed Elevations |
| Purpose | BR |
| Scale | 1:50 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A1 |
| Date | 16/10/26 |
| Checked Date | 30/10/26 |
| Approved Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-201 |
| Version | P1 |
| File | YD2603-APP-XX-XX-DR-B-202 Proposed Elevations.dwg |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373
Proposed Section
Section A - A'
Scale: 1:20
IMAGE: Section through the proposed accessible toilet extension showing the cold roof, roof slope of 27°, wall construction, floor construction, foundations, drainage channel, door threshold and internal accessible toilet fittings. The drawing includes a floor plan reference marked “Not to scale”.
Notes
- Proprietary tiled ventilated dry ridge system.
- Second hand stone slates to match existing building (utilising slates from existing roof, north elevation, that are being removed to facilitate new roof installation); nailed to new 25 x 50 tanalised battens at centres to match slating.
- Kingspan Nilvent (or equal and approved) breathable membrane on C16 145 x 47mm sw timber rafters at maximum 600mm c/c's; fixed using truss clips to 100 x 75mm treated sw wall plate, strapped down with 1200 x 30 x 5mm galvanised steel straps at maximum 1.8m c/c's.
- Over fascia vents to provide equal to 10mm continuous air gap.
- Proprietary eaves ventilation trays to be installed between rafters as indicated to prevent insulation blocking ventilation - min. 50mm ventilation gap required.
- Roof insulation at ceiling level - 100mm Knauf Earthwool Loft Insulation Roll 44 Combi laid between ceiling joists and two layers laid over joists runnig perpendicularly; total thickness 300mm.
- C16 145 x 44mm sw timber ceiling joists at 450mm c/c's.
- External wall construction: 125mm thick natural stone outer leaf; 100mm cavity with 90mm thick Kingspan Kooltherm K8 cavity board foil faced insulation batts (or equivalent board at 0.022 W/m²K); 100mm thick Aglite Ultima (or equivalent) load bearing blockwork 7.3N/mm² inner leaf. Cavity wall ties to be Ancon ST1 Type tie to PD 6697 (heavy duty), or equal to, at 750mm horizontal c/c's and 450mm vertical; ties to be within 150mm of window and door jambs.
- Continuous damp proof membrane at minimum 150mm external FFL.
- Preformed cavity trays to be installed.
- Floor construction: 2.5mm vinyl safety flooring on; min. 65mm sand/cement screed on; 500-gauge polythene separating layer on; 100mm rigid board insulation, Kingspan Kooltherm K3, or equivalent; 30mm thick perimeter slab upstand insulation to prevent cold bridging, on; 150mm concrete slab on; 1200-gauge damp proof membrane, lapped over inner leaf blockwork and into masonry joints on; 50mm sharp sand blinding on; minimum 150mm well consolidated hardcore sub base; the junction detail between existing and new foundations tbc following further site investigations.
- 300mm wide 7.3N/mm2 foundation blocks on; 650 x 300mm deep concrete strip foundations to be minimum 900mm deep and to the approval of the BCO; weak mix concrete infill to base of cavity.
- New door to be fully compliant with Approved Document Part B providing an effective clear width of 1000mm and level threshold aluminium trim Zedex CPT or equivalent below threshold trim.
- 100mm ACO MultiDrain PPD drainage channel to door threshold, connected into new SVP.
Drawing Information
| Field | Information |
|---|---|
| Client | Yorkshire Dales National Park |
| Project name | Linton Accessible Toilet Extension |
| Drawing Title | Proposed Section |
| Purpose | BR |
| Scale | 1:20 |
| Drawn | IC |
| Checked | BL |
| Approved | SS |
| Original Size | A1 |
| Date | 16/10/26 |
| Checked Date | 30/10/26 |
| Approved Date | 30/10/26 |
| Drawing Number | YD2603-APP-XX-XX-DR-B-300 |
| Version | P1 |
| File | YD2603-APP-XX-XX-DR-B-300 Section.dwg |
Wharfebank House, Wharfebank Mills, Ilkley Road, Otley LS21 3JP Tel: 01609 797373